Lab machine integration · Bangladesh

Sysmex, Mindray, Cobas, Horiba, Erba — results go straight to the report.

The hospital system listens to your analysers over the network. What the machine measured is what prints on the report, with no transcription in between. Orders can go the other way for named analysers, commissioned and validated at your site.

What you get
Analysers named and supported
36
Plus standard ASTM / HL7 machines
not a fixed list
How they connect
Serial RS-232 or network
Support for a new machine
Arrives over the network
Quality-control runs
Stay in your lab
Priced
Per connected machine
Orders can go the other way for named analysers, commissioned on your bench — the full list is below.

Results coming in

36 named analysers, and standard machines beyond them.

ASTM, HL7 or the vendor’s own format, over serial or network. Thirty-six machines are named and supported by name; standard ASTM and HL7 analysers beyond that list are read too, so the list is not a limit.

Sysmex
XN-550
Mindray
BC430 · BC760 · BC-20s · BC-2800 · BS-430
Roche
COBAS C311 · COBAS E411
Horiba
Pentra XLR · Pentra 400 · Yumizen · Yumizen H550 · ABX Micros ES-60
Siemens
ADVIA CP · Dimension RxL
bioMérieux
VIDAS (Minividas) · VIDAS KUBE
Abbott
i800
Snibe / YHLO
Maglumi · iFlash
Erba
EC90
Also named
Laura XL · Rayto · Finecare Wonfo · Dymind · Celltech G · JUNO · AER 3000 · FUS 1000 · Mission HA-360 · Faca-280 · Abacus 380 · Maccura i1000 · Diatron Pictus · CXL PRO · HTSH-2000

Orders going out

Available for named analysers, commissioned at your lab.

The system tells the analyser what to run — either by sending the worklist, or by answering when the machine asks. One of these is ported from an implementation already proven in production; the rest are built from the manufacturer’s own specification and commissioned on your bench before clinical use. We say which is which because it matters.

Horiba / Diatron Yumizen P8000
Ported from a proven working implementation
Horiba Yumizen H550 · Pentra C400 · Pentra XLR
Built to the maker's spec — commissioned at your lab
Mindray BS-430
Built to the maker's spec — commissioned at your lab
Snibe Maglumi · YHLO iFlash
Built to the maker's spec — commissioned at your lab
ADVIA Centaur CP · Centaur XPT
Built to the maker's spec — commissioned at your lab
Maccura i800 · i1000 · Dymind
Built to the maker's spec — commissioned at your lab
Diatron Pictus · CXL PRO · HTSH-2000
Built to the maker's spec — commissioned at your lab
Orphée Mythic 22 AL · VIDAS KUBE
Built to the maker's spec — commissioned at your lab
Parsing a machine's results is not the same as being able to order to it. We check your exact model number.

How it is put together

A small program in your lab, and a parser that updates itself.

Analysers do not speak to hospital systems directly — they speak their maker’s dialect down a serial cable or a network socket. So a small program runs on a PC in your lab, listens to each machine, and hands the result to your MediSpa server.

The part that reads each machine’s format is not baked into that program: it is fetched over the network and checked every few minutes. When we add support for an analyser you have just bought, it appears in your lab without anyone visiting, and without you installing anything.

The licence lives on that PC and is checked without phoning home, so a dead line never stops your lab working.

What sits where
In the lab
A small program on a PC, next to the machines
To the analyser
Serial RS-232, or over the network
To your server
Sent straight to MediSpa
New analyser support
Arrives over the network — no visit, no new install
Quality-control runs
Stay in the lab, never sent to the report
If the internet drops
The lab PC and your server are both on your own network

Radiology

The scanner pulls the patient from the system. Nobody retypes anything.

A radiographer typing a patient name at the CT console is the single largest source of mismatched studies in a busy department. With MediSpa the CT or X-ray pulls the scheduled patient and order from its own worklist, and the hospital system knows the moment the scan starts and finishes.

Small vendors in this market essentially never implement this properly. We do, and you can check it.

Worklist to the modality
DICOM Modality Worklist
Status back from the modality
MPPS: started, completed, by whom
Reports
Back into the hospital record
What it prevents
Mismatched studies from a name typed at the console

The service wrap

You pay for the machines you connect. We set it up, license it and look after it.

The connection runs on a small program at the lab PC. We create the account, set the package, manage the subscription and add support for a new machine remotely. You never deal with the software vendor behind it, and you are never asked to install anything.

Pricing
Per connected analyser
Licensing
Held and administered by us
New analyser support
Delivered over the network; no site visit
Protocols
ASTM E1394 · HL7 v2.x · RS-232 · TCP/IP

Straight answers

The questions buyers ask

What is the difference between results in and orders out?
Results in: the analyser sends what it measured, and it lands on the report. This is mature and works for every family listed. Orders out: the software tells the analyser which tests to run on which sample, so nobody keys the order at the machine. This exists for the analysers listed and is commissioned and validated at your site before it is used clinically.
Is it two-way with my machine?
Possibly. A machine that talks both ways is not the same as one we send orders to — the second needs an order builder for that exact model. The list on this page is the honest answer; we will confirm against your model number before promising anything.
What protocols does it use?
ASTM E1394 and HL7 v2.x over RS-232 serial or TCP/IP, plus vendor-specific formats where a manufacturer has its own. Radiology uses DICOM Modality Worklist and MPPS.
Who supports the connection?
We do. The connection software is licensed to us and administered by our team. Adding a new analyser does not need a visit — the parsers are delivered over the network to the lab PC.
How is it priced?
Per connected machine, separately from the monthly fee for the hospital software. Ask for a quote with your analyser list.

Next step

Tell us the exact model numbers

We will answer machine by machine: results in, orders out, or not yet — before you sign anything.